1. |
    Protek A333 network analyzer |
| |
- Frequency Range : 0.3 to 3200MHz
- Impedance : 50? (75?)
- Test Port Connectors : N-type Female
- Number of Test Ports : 2
- Frequency Accuracy : ±5 ppm
- Frequency Resolution : 1mHz
- Number of Test Points User-Selectable : 2 to 10001
- IF bandwidth settings1/1.5/2/3/5/7/10 step : 1Hz to 30kHz
- Dynamic RangeIF Bandwidth 10Hz : 2 to 3200MHz > 125dBTyp. 130dB
For
more information about Protek A333 click here
|
|
2. |
    Protek 3290N - Hand-Held 2.9 GHz RF Signal Strength Analyzer |
| |
The World-First Hand-Held Field Strength Analyzer with Wide Band Reception ranging 100kHz to 2,900MHz
- 100? ~ 2,900? measurement range (3290N Only)
- Measure and Demodulates W-FM / N-FM / AM / SSB signals
- PLL tuning system for precise frequency tuning
- Built-in Frequency Counter and Speaker
- LED Backlight LCD (192X192 dots)
- RS-232C for PCinterface and printer (8 pin mini Din)
- Menu Driven for Various Function
For
more information about Protek 3290N click here
|
|
|
|
Bird Electronic |
 |
1. |
 Bird
Electronic SA-1700EXP
Site Analyzer 25 to 1700 MHz (upgradeable to 6 GHz) |
| |
 
 Warranty: 3
months
 
 Data sheet
|
|
2. |
 Bird Electronic 5012 Wideband
Power Sensor 350 to 4000 MHz, 150 mW to 150 Watts |
| |
 
 Warranty: 3
months
 
 Data sheet |
|
| ¹ |
Cod |
Description |
| |
|
|
| 1.0 |
SA-1700EXP |
Site
Analyzer, 25-1700 MHz, With Power Measurement |
| |
|
S/N
061400158 (demo instrument with 3 months warranty) |
| 2.0 |
CAL-MN-C |
Calibration
Combo, (M)N |
| |
|
S/N
32436 (demo instrument with 3 months warranty) |
| 3.0 |
TC-MNFN-1.5 |
Test
Cable M/F-N,1.5M Armored Phase Stable DC-6GHz |
| |
|
|
| 4.0 |
5012 |
Wideband
Power Sensor 350 MHz to 4000 MHz 150 mW to 150 W |
| |
|
S/N
071200189 (demo instrument with 3 months warranty) |
| 5.0 |
VPM-KIT-E |
Virtual
Power Meter Software - 230V (used with 5012 Power
Sensor) |
|
|
|
LEXXI
T810
|
 |
|
|
1.
|
    LEXXI
T810 - Universal headheld cable fault locator from 0
to 3000 m
|
| |
- Use
the latest generation, hand-held cable fault locator from
the people who
invented the world’s first, and you hold two vitaladvantages:
time saving
innovation and experience-led performance.
- The
Lexxi T810 gives genuine universal performance for short
and long range applications on all types of metallic cable,
with switchable settings for CATV,
75½ coax, datacom & telecom, twisted pair, LV power distribution
and
50 ohm coax.
- Innovative
features* result in a versatile, cable-test instrument
that is
remarkably easy to use.
- Large
back-lit display, tactile push buttons and ability to
operate in temperatures
as low as -20ºC allow use in a vast range of locations
and conditions.
- Accurate
to 20cm on shortest range.
- Automatic
cable attenuation compensation ensures easy location of
faults at all distances, without the need for a balance
control.
- Automatic
default settings of pvf, cable impedance and cable attenuation
compensation are selected by cable type.
For
more information about LEXXI T810 click here
(
163Kb PDF )
|
|
|
|
SunLite
E1
|
 |
|
| |
2
Mbps testing in the palm of your hand! Available in 75 ohm
and 120 ohm models, this tiny tester will conduct and store
a variety of vital tests.
Highlights
- 2.048
Mbps transmit,receive, and external clock
- E1
bit error rate testing (ITU-T G.821)
- ITU-T
G.826 and M.2100 analysis
- Level
and frequency measurements
- Programmable
NFAS words
- Alarm
Generation/Error Injection
- TERM,
PMP (Monitor), High Impedance
- Drop
and insert capability (N or Mx 64k)
- store
up to 10 test results and 10 user profiles
|
|
|
|
SunLite
E1 Color Brochure
(pdf) 437 kb
|
|
|
|
|
|
Metrel
|
 |
|
|
1.
|
    Multi
LAN 200 Cable Analyser
|
| |
Cable
Certifying and Troubleshooting for everyone
Standards:
TSB-67
TIA 568 A Cat 5
ISO 11801 Class D
EN 50173
|
|
Multi LAN 200
|
| |
- Provides
all cable tests - Basic and Channel Link Cat 5
for verification
of LAN installations. Extended Frequency
Measurement.
- Delivers
Tracing, Talk and Test facilities at the same time.
- Supports
different world recognized Cat 5 cable standard like:
EN 50173, ISO/IEC 11801, TIA Cat 5.
- Offers
powerful troubleshooting tools.
- Includes
LAN Link PC Software for Test Report Evaluation and
Graphic Analysis of measured data.
- Basic
and Chanel Link etc.
- Has
small power consumption.
- It
is easy to use.
- Excelent
price / performance ratio.
Accessories
--------------------------------------------------------------------------------------------------------
Standart
Set
- Instrument
Multi LAN 200
- Remote
unit LANremote
- Patch
cables 2 m, 2 pcs
- LAN
Link PC Software
- RS
232 cable
- Carrying
bag
- Instruction
manual
- Declaration
of Conformity
- Production
Verification data
- Declaration
of warranty
Optional
Accessories
- Instrument
Multi LAN 200 as Smart Remote Unit
- Fiber
optic set
- Headphones
set
- Tracer
- Battery
charger + NiCd battery pack
----------------------------------------------------------------------------------------------------------------------------
|
|
|
|
Protek-3201
|
 |
|
2GHz
Field Strength Analyzer
 |
Features
- Frequency
Range : 100KHz ~ 2060MHz
- WFM/NFM/AM/SSB
modulated signals may be measured.
- Signal
Levels up to 160Channels can be displayed simultaneously
on the LCD
- PLL tuning
system for precise frequency measurement and tuning
- Built-in
Frequency Counter
- LED Backlight
LCD (192 x 192DOTS)
- Hand-held
and Battery Operated
- All functions
are menu selected.
- RS232C
for PC interface and printer
- Built-in
speaker
Specification
- Reception
Frequency
1) Frequency Range : 100KHz ~ 2060MHz
2) Step Frequency : 5KHz and 6.25KHz STEP at 5KHz to 9995KHz
3) Accuracy : ±25ppm
4) Reception Mode : NFM/WFM/AM/SSB
5) Channel Memory : 10Bank x 160ch (1,600 Channels)
6) Data Memory : 10Bank x 160ch (1,600 Channels)
7) Setup Memory : 16Bank
8) Input Impedance : 50 Ohms
9) Max. Input Voltage : Max. 5Vrms
10)Reception sensitivity : Approx. 0~6dbµV EMF (S/N : 12dB at
N-FM,10dB at W-FM)
- Level
Measurement
1) NFM
2) Range : -10dBµV to 40dBµV (from 1MHz to 2000MHz)
3) Resolution : +/- 0.5dBµV
4) Accuracy : +/- 3dB (at an ambient temperature and with a
calibrated frequency)
5) Bandwidth : Approx. 12.5KHz(-6dB)
6) WFM/AM/SSB
Range : 0dBµV to 50dBµV (from 10MHz to 2000MHz)
Resolution : +/- 0.5dBµV
Accuracy : +/- 3dB (at an ambient temperature and
with a calibrated frequency)
Bandwidth : WFM : Approx. 180KHz(-6dB) AM/SSB :
Approx. 2.4KHz
(-6dB)
7) Function display mode
Multi bar graph display (5,10,20,40,80,160 channels)
Single Bar graph display
Spectrum Analyzer display
Difference Mode display
Frequency Counter display
8) Sweep Mode
Single / Normal / Free / Free Singe
9) Squelch Function
Squelch level is displayed with a bar graph and
a digital readout
- Frequency
Counter
Range : 9MHz ~ 2060MHz / 9MHz ~ 2000MHz 150mVrms
Accuracy : ±50ppm ±1 count
Resolution : 1KHz
Response Time : 0.512 sec
Sensitivity : 20MHz ~ 1000MHz 100mVrms
Input Impedance : 50 Ohms
Data Memory : 10CH
Max Input Voltage : Max 5VRMS
- LCD
: 192 x 192DOT LCD, Backlighted
- Operating
Temperature & Humidity : 0 to 40°C & 35 to 85% RH
- Storage
Temperature : -10 to 50 °C
- Dimension
& Weight :
105(W) x 220(H) x 45(D)mm / Approx. 700g (Antenna is not included)
- Accessories
:
- Supplied Accessories : Antenna (Receive only), RS-232C cable,
Carry case,
Manual, AA type alkaline batteries
x
6pieces
- Optional Accessories : 75 to 50 Ohms matching pad, ATT 20dB,40dB,
F-BNC
adapter, AC adapter, Car adapter,
Mini
printer(RS-232C), Block voltage unit
Software
for PC interface
|
|
|
Protek-2700
|
 |
|
RF
Power Meter
 |
Features
- Light
weigh,hand-held instrument
- Frequency
Range over 2GHz
- Hold/
Run Modes
- Meter
zero function
- Large,
3 1/2 digit liquid crystal display
- CW power
0.1 mW to 500mW; limited duration to 1W
- Full-scale
ranges - 2mW, 20mW,200mW,2000mW
- Hight-impact
case,rugged design
Specification
- Frequency
Range : 10MHz to 2GHz usable 100KHz to 2.7GHz
- Power
Input Range :
1.999 mW
19.99 mW
199.9 mW
1999 mW
- Accuracy
:
-20C~30C : ±10% of Full Scale,10MHz to 1GHz
±15%
of Full Scale,1GHz to 2GHz
-10C~40C : ±15% of Full Scale,10MHz to 1GHz
±20%
of Full Scale,1GHz to 2GHz
- Meter
Zero :
Push button press to zero meter prior to application of RF Power
- Meter
Hold :
Push button
press holds last reading; press to again to resume
- Max
Input protection :
500mW continuous,no
damage;1W for 10 seconds max
- Input
Connection : Type
N Female : 50 ohm,Return Loss <-18 dBRL
- Operation
Temperature : +10°C to 40°C
- Storage
Temperature : -20°C to 70°C
- Dimensions(approx)
:
89mm(w) x 160mm(h) x 46mm(d)
- Weight
: Less than 2 pounds
|
|
|
Protek-6510
|
 |
|
Real
Time Oscilloscope
 |
Features
- High Sensitivity
(1mV/div) and 2Channel, Dual Trace 6 inch Internal Grid
- ALT MAG
: Simultaneous Sweep waveform, x1 and x10(x5)
- ALT TRIG
: Synchronization between two different signals
- TV Sync.
: Stable TV signal observation
- AUTO Focus
: Auto-correction of focus diversio
Specifications
- CRT
Acceleration Voltage : 12KV
Valid Area : 6 inch (8 x 10 div) (div ~10mm)
- Vertical
Deflection
|
CH1,
CH2 Sensitivity
|
5mV/div~5V/div,
(1-2-5 STEP,10 RANGE)
1mV/div~1V/div (X5MAG)
|
|
Bandwidth
|
DC
: DC-100MHz
AC : 10Hz~100MHz
|
|
Input
Impedance
|
1M
Ohm±2%, 25pF±3PF
|
|
Max.
Input Voltage
|
300V(DC+AC
peak)
|
|
Input
Coupling
|
AC-GND-DC
|
|
Operation
Mode
|
CH1,
CH2, ADD, DUAL
|
|
Chop
Frequency
|
300KHz
|
- Horizontal
Deflection
|
Sweep
Mode
|
A,
B INT, B, B TRIG'D, XY, A ALT B
|
|
Sweep
Time
|
0.05µS/div
~ 0.2 S/div
1-2-5 STEP, 21 RANGE
5us/div~0.2ms/div(x 10MAG)
|
|
A
Sweep Expansion
|
10
Times Expansible from the center of CRT
|
|
A
Sweep Time Accuracy
General
Expansion
|
±3%
±5% (Except 0.1, 0.05uS/div)
|
|
Continuous
Variation of Sweep Time
|
up
to 2.5 times
|
|
HOLD
OFF
|
up
to 2 times variable
|
|
B
Sweep Time
|
0.05µs/div
~ 10µs/div
1-2-5 STEP, 8 RANGE
5ns/div~10us/div(x 10MAG)
|
|
B
Sweep Expansion
|
10
Times Expansible from the center of CRT
|
|
A
Sweep Time Accuracy
General
Expansion
|
±3%
±5% (Except 0.1, 0.05uS/div)
|
|
Delay
Time
|
0.2us
~ 2 sec
|
- Triggerin
|
Signal
Source
|
INT,
CH2, LINE, EXT
|
|
Trigger
Coupling
|
AC
Only
|
|
Sync.
Type
|
AUTO,
NORM, TV-H, TV-V
|
|
Sync.
Polarization
|
+
or -
|
|
Sensitivity
|
|
|
|
Frequency
|
INT
|
EXT
|
|
AUTO
|
10Hz
~ 10MHz
|
0.5div
|
200mV
|
|
10MHz
~ 100MHz
|
1.5div
|
500mV
|
|
NORM
|
DC
~ 10MHz
|
0.5div
|
200mV
|
|
10Hz
~ 100MHz
|
1.5div
|
500mV
|
|
TV
Sync.
|
INT
: 1 div
EXT : 1 Vp-p
|
- X-Y
MODE : CH1-X, CH2-Y
Sensitivity : Same as Vertical Deflection
Frequency Characteristics : DC-2MHz,
Phase Difference DC 100KHz 3°
- External
Input
Input Impedance : 1M Ohm, 25pF
Max. Input Voltage : 30V (DC + AC peak)
- Z axis
Sensitivity
: Darken +5V Positive Signal
Bandwidth : DC ~ 2MHz
Input Impedance : About 20K Ohm
Max. Input Voltage : 50V (DC+AC peak)
- Correction
Voltage
Waveform
: 1KHz
Amplitude : 0.5V, ±3%
Symmetry : 48 : 52
- Operation
Voltage
: 100V/120V/220V ±10% 240V (216V ~ 250V)
Frequency : 50 ~ 60 Hz
Power Consumption : 55 W
- Dimension
& Weight
322(W)x135(H)x368(D)mm,
7.5kg
- Etc.
Operation
Temp. and Humidity : 0°C~40°C, 35 ~ 85% RH
Usage Temp. and Humidity : 10°C~35°C, 45 ~ 85% RH
Reservation Temp. and Humidity : -20 ~ 70°C
- Accessories
- Power
Cord 1EA
- Fuse 2EA
- Probe 2EA
- Manual 1EA
|
|
|
Protek-2100
|
 |
|
PC
Based Scope Card
 |
Features
- Dual Channel
- 100 Msps
per Channel, 30MHz Bandwidth
- Parallel
Port PC Connection
- Auto Calibration
- Auto Setup
- 50MHz
FFT Spectrum Analyzer
Specifications
- Requirements
IBM compatible PC(Pentium) 32M RAM/100MB of free hard disk space
Windows 95/98
- PC Connection
: Parallel
- Power
: DC ±8V
- Channel
: 2Channel
- Impedance
: 1MOhm25pF
- Coupling
: AC/DC/GND
- Bandwidth
: DC~30MHz -3dB
- Resolution
: 8Bit
- Voltage
Range : 50mV~5V, 1,2,5 7Steps
- Display
area : 8x10div
- Accuracy
: ±3%(Gain), ±0.01%(Time)
- Time Base
Range : 50ns~320s
- Input
Range : ±50V
- Max. Input
: ±100VDC Continuous ±250V(DC+AC) Transient
- X-Y :
±3%
- Auto Setup
: DC~30MHz, Frequency Counter
- Sample
Clock Rate :1Hz ~ 100MHz
- EXT Trigger
Input : TTL only
- Trigger
Type : ±Slope
- TV - V/H
: Yes
- Trigger
Level : ±3div (DC only)
- Trigger
Type : Analog
- Trigger
Source : CH1, CH2, EXT
- Mag (Time)
: OK
- Offset
Range : ±4div
- Memory
Depth : 32KB/CH
- Max Sampling
Rate : 100MSPS/CH, Dual 100MSPS
- Auto Calibration
: OK
- Trace
Display : Point/Line
- Grid :
On/Off
- Vertical
Mode : CH1, CH2, Dual , ADD
- Horizontal
Mode : AUTO, NORM, SINGLE
- Single
: DC ~ 30MHz
|
|
|
MIT-3260/3100
|
 |
|
Spectrum
Analyzer
Features
- Accurate,
Stable Frequency and Level
- Digitally
Synthesized RF System
- Frequency
range of 1 GHz/ 2.6GHz
- Input
Levels of - 100dBm to + 20dBm
- On-screen
markers with Signal Level readout
- Front
Panel setup save and recall
- Flicker-free
scope display
- Optional
: Tracking generator(only for 3100), High Stability Oscillator

Specifications
|
Model
|
MIT
3100
|
MIT
3260
|
| Frequency
Range |
10MHz
to 1GHz
|
10MHz
to 2.6GHz
(Except 1.15GHz~1.5GHz)
|
| Frequency
Resolution |
1KHz
Center Frequency resolution |
| Frequency
stability |
±
10ppm(Standard time base)
± 2.5ppm(HSO Option) |
| Frequency
Spans |
Zero
span,
2KHz to 100MHz per division in a 2-5-10 sequence |
| Resolution
Bandwidths |
3KHz,30KHz,220KHz,4MHz
±15% Accuracy |
| Video
Bandwidths |
1.6kHz/90kHz |
| RF
Sweep Rate |
200mS / div. |
| Input
Level Range |
-100dBm
to +20dBm |
| Input
Level Overload |
+30dBm
for 1 minute max,any scale,
DC block to 50VDC |
| Level
Accuracy |
±1.5dB
|
| Level
Linearity |
±1.5dB
over -70dB (Range for 3kHz RBW) |
| Level
Flatness |
±1.5dB |
| Reference
Level Range |
-30dBm
to +20dBm, 10dBm Step |
| Display
Range |
75dB
usable |
| Noise
Floor |
-140dBm/Hz Typical |
| Phase
Noise |
<
-77 dBc/Hz @30KHz offset from carrier |
| Power
Source |
+12VDC
Input, 1.5A |
| Dimensions(approx.) |
254mm(W)
x 95mm(H) x 273mm(D) |
Applications
- IF, RF
Circuits and Systems
- Calibration
and Verification testing
- Remote
and mobile monitoring
- Cellular
and PCS phones and base stations
- Consumer
wireless remotes, microphones, monitors
- Television
- Two-way
radio
- Trunk
radio
- Field
Services
- Manufacturing
|
|
|
IFR
/ Marconi Instruments /
|
 |
|
|
1.
|
    2399
- 9 kHz to 2.9 GHz Spectrum Analyzer
|
| |
|
A
spectrum analyzer with outstanding
performance and a user friendly visual
interface simplifying many complex
measurements
|
Download
2399 datasheet here
|
SPECIAL
15% DISCOUNT OFFER
|
| |
- 9
kHz to 2.9 GHz fully synthesized frequency range
-
Lightweight, portable and rugged construction at 9.4 kg
-
Excellent TFT color display
-
Comprehensive marker facility
-
Wide input signal range +30 dBm to -110 dBm
-
Optional full range tracking generator
-
Semi-automated measurements
-
Low phase noise
-
Floppy disk drive
-
Extremely user friendly MMI reduces risk of operator error
-
Auto-tune facility
-
GPIB as standard
- AM/FM
demodulation
Versions
and Accessories -------------------------------------------------------------------------------------
2399/00
9kHz to 2.9 GHz
basic spectum analyzer
2399/01 2399/00
with tracking generator
2399/02 2399/00
with quasi-peak detector and hig stability time base
2399/03 2399/00
with tracking generator andhigh stability time base
2399/04 2399/00
with high stability time base
2399/05 2399/00
with tracking generator, high stability time base and
quasi-peak detector
2399/06 2399/00
with tracking generator and quasi-peak detector
Supplied
Accessories
Front
cover
Operation manual
Program manual
AC supply lead
RS-232 cable
2 x 250V, 3015 A fuses
Soft carry case
Optional
Accessories
Maintenance
manual
AC2621 Rack
Mount kit
59999/170 Return loss bridge
(5 MHz to 2 GHz, type N (f))
AC4250 5
Ohm N to 75 Ohm BNC
AC5008 D
block N type
AC8700 UHF
antenna
AC2601 Soft
carry case
----------------------------------------------------------------------------------------------------------------------------
Warranty:
24 months
|
|
|
|
IFR
/ Marconi Instruments /
|
 |
|
|
1.
|
    2305
Modulation Meter
|
| |
    Including:
AC SUPPLY LEAD
    Specification:
Frequency range: 50 kHz
to 2.32 GHz
Accuracy: 0.5%
Internal calibrator
Fast automatic tuning
Low Noise
Non volatile memory
GPIB programmable
AM, FM and PhM masurements
Frequency and power measurements
Distortion and weihted measurements
Excellent stereo separation
Overload protection
   Price:
$ 15 099
   Discount: 30%
   Warranty:
3 months
   End
Price: $ 10 569
|
SINAD
and RF power measurements complement the high accuracy measurements
of AM, FM and PhM
EX-DEMO
|
|
|
|
IFR
/ Marconi Instruments /
|
 |
|
|
1.
|
    2022C
AM/FM SIGNAL GENERATOR 10 kHz to 1 GHz – 1 unit
|
| |
    Including:
AC SUPPLY LEAD
    Specification:
Frequency range: 10 kHz
to 1 GHz
Output range: -127 dBm to
+13 dBm
AM range: 0 to 99.5%
FM range: 0 to 99.9 kHz
   Price:
$ 5 000
   Discount: 30%
   Warranty:
3 months
   End
Price: $ 3 500
|
EX-DEMO
|
|
|
|
IFR
/ Marconi Instruments /
|
 |
|
|
1.
|
    2398
Spectrum Analyzer with Tracking Generator – 1 unit
|
| |
    Including:
AC SUPPLY LEAD
Operation Manual
Program Manual
    Specification:
Frequency range: 9 kHz
to 2.7 GHz
Input range: -105 dBm to
+20 dBm
Tracking Generator
AM/FM demodulation
Split Screen Operation
Low Phase Noise
Lightweight: 8.2 kg
    Warranty:
3 months
|
EX-DEMO
|
|
|
|
IFR
/ Marconi Instruments /
|
 |
|
|
1.
|
    2399
Spectrum Analyzer with Tracking Generator – 1 unit
|
| |
    Including:
AC SUPPLY LEAD
Operation Manual
Program Manual
    Specification:
Frequency range: 9 kHz
to 2.9 GHz
Input range: -110 dBm to
+30 dBm
Tracking Generator
AM/FM demodulation
Split Screen Operation
Low Phase Noise
Auto Tune
Semi-automated measurements
Excellent TFT Display
Floppy Disk Drive
Lightweight: 8.2 kg
    Warranty:
3 months
|
EX-DEMO
|
|
|
SPECIAL
OFFERS FOR USED EQUIPMENT
from TEKTRONIX and HITACHI
|
|
|
TEKTRONIX
|
 |
|
|
1.
|
    Tek2236
Oscilloscope, 2 ch., 100 MHz, counter - 1 unit
|
| |
    Including:
AC SUPPLY LEAD
   End
Price: $ 1 150
 
 Warranty:
3 months
|
| | |