AC/DC
CLAMP METER With Power
Features
- 4,000
Count
- 40 Segment
Bargraph
- AC/DC
1000A
- CE Marking
(CAT III)
- Power,
Apparent Power, Power Factor(307 Only)
Specification
|
DC Voltage
|
Range
|
400mV
|
4V
|
40V,400V,600V
|
|
Accuracy
|
±(0.5% rdg+ 3dgt)
|
|
Input Impedance
|
100M
|
11M
|
10M
|
|
Max Input
|
1000V DC and peak
|
|
AC Voltage
|
Range
Accuracy
Input Impedance
Max Input
|
4V,40V,400V,600V
±(1.5% rdg+ 5dgt)
10M
750V DC and AC peak 50Hz~500Hz
|
|
DC Current
|
Range
|
400A
|
1000A
|
|
Accuracy
|
±(2.0 rdg+ 8dgt),0~100A/
±(2.0%rdg+5dgt),100A~1000A
|
|
Resolution
|
0.1A
|
1A
|
|
Overload Port
|
1000A(with in
1 minute)
|
|
AC Current
|
Range
|
400A
|
1000A
|
|
Accuracy
|
±(2.0 rdg+ 8dgt),0~100A/
±(2.0%rdg+5dgt),100A~1000A
|
|
Resolution
|
0.1A
|
1A
|
|
Overload Port
|
1000A(with in
1 minute)
|
|
Resistance
|
Range
Accuracy
Resolution
Max Input
|
400 4K
40K 400K 4M
10M
±(2.0%rdg+5dgt),100A~1000A
100m 1 10
100 1k
10k
600Vrms
|
|
Frequency
|
Range
Accuracy
Resolution
Max Input
|
100Hz 1kHz
10KHz 100KHz 1MHz
±(2.0%rdg+5dgt),100A~1000A
0.01Hz 0.1Hz 1Hz 10Hz
100Hz
250V DC or rms
|
|
Model
|
|
305
|
307
|
|
Power
|
Range
Accuracy
Resolution
Max Input
|
600kW
±(2%rdg+3dgt)
1W
1000V/1000A
|
NO
|
Yes
|
|
Apparent Power
|
Range
Accuracy
Resolution
Max Input
|
600KVA
±(2%rdg+3dgt)
1VA
1000V/1000A
|
|
Power Factor
|
Range
Accuracy
Resolution
Max Input
|
0.03~1
±(2%rdg+3dgt)
0.01
1000V/1000A
|
- General
Measuring : Dual Integration
Mode
Display : 3 3/4 digits LCD,MAX
Reading of 3999
Bar Graph Display : 40 Segments
Range : Auto or Manual Ranging
Polarity : Automatic no indication
for positive Polarity,Minus(-) sign for
Negative
Polarity
Sampling : Digital 2 Times/sec
Bar graph 20 Times/sec
Low Battery Indication : "BAT"
Light 2.4V ±0.3V
Operating Temperature : 0°C to
40°C(below 80R.H) Non-Condensing
Temp Condition : (0°C~18°C),(28°C~40°C)
Accuracy x 0.1
Storage Temperature : -20°C to
60°C(below 80R.H) Non-Condensing
Power Supply : 1.5V Battery(AAA)
X2pcs
Auto Power-off : 30Munutes
|