Protek A333




 

The Protek A333 network analyzer has been developed and produced for higher frequency resolution and more convenient user interfaces than other industry-leading products in the same 3GHz class. The architecture of A333 includes 1 mHz of high frequency resolution with a 3.2 GHz frequency range. The Protek A333 network analyzer offers a 10.4inch color LCD touch screen and a variety of display functions, which allow you to optimize your convenience. The Protek A333 network analyzer builds on GSI's 36-year legacy of excellence to bring new standards to the radio frequency (RF) test and measuring industry.

Measurement range

- Frequency Range : 0.3 to 3200MHz
- Impedance : 50Ω (75Ω)
- Test Port Connectors : N-type Female
- Number of Test Ports : 2
- Frequency Accuracy : ±5 ppm
- Frequency Resolution : 1mHz
- Number of Test Points User-Selectable : 2 to 10001
- IF bandwidth settings1/1.5/2/3/5/7/10 step : 1Hz to 30kHz
- Dynamic RangeIF Bandwidth 10Hz : 2 to 3200MHz > 125dBTyp. 130dB

Test port output

- Power range : -45 to +10dBm
- Power accuracy : <1.0dB
- Power resolution : 0.05dB
- Harmonic distortion : -30dBc
Test port input

- MatchWithout system error correction : > 25dB
- Damage level : +26dBm
- Damage DC voltage : 35V

External Reference Signal Input/Output

- Frequency : 10MHz

Measurement Accuracy

1. Accuracy of Transmission Measurement (magnitude/phase)

- Specifications are based on a matched DUT, a measurement bandwidth of 1 Hz,
and a nominal source power of -5dBm +15 to +5dB 0.2dB/2.0°

+5 to -50dB 0.1dB/1.0° , -50 to -70dB 0.2dB/2.0° , -70 to -90dB 1.0dB/6.0°

2. Accuracy of Reflection Measurement (magnitude/phase)

- Specifications are based on a matched DUT, a measurement bandwidth of 1 Hz, and a nominal source power of -5dBm

0 to -15dB 0.4dB/4.0° , -15 to -25dB 1.5dB/7.0° , -25 to -35dB 4dB/22.0°
Trace Stability

Temperature DependencePer one degree of the temperature variation : 0.02dB
Trace Noise MagnitudeIF bandwidth 3kHz : 0.001dB rms

Other capabilities

1. Internal hard disk drive
Store and recall instrument states, calibration data, and trace data on internal hard drive. Trace data can be saved in CSV (comma separated value) format. Instrument states include all control settings, limit lines, segment sweep tables, and memory trace data.

2. USB
Instrument states, calibration data, and trace data can be stored on an external USB drive.

3. Screen hardcopy
Printouts of instrument data are directly produced on a printer. The analyzer provides USB and parallel interfaces.

4. Familiar graphic user interface
Protek A333 provides graphic user interface based on Windows. There are three ways to operate A333 manually: a hard-key interface, a touch screen interface, mouse interface.

5. Limit lines
Defining the test limit lines that appear on the display for pass/fail testing. Defined limits may be of any combination of horizontal/sloping lines and discrete data points.

Programming functions

COM/DCOM Automation

Remote Control
LAN, GPIB (optiona)
Operating environment

Temperature : +5 to +40°c
Dimension ( W x H x D ) : 426 x 222 x 270 mm
Weight : 10.6 kg
Power supply : 100 to 240 VAC / 47 to 63 Hz


  Back to Protek Products or

For further information, please
Contact Us

Request a Quote

 


GIGA Electronics Ltd. - Innovative Electronic Solutions

At GIGA Electronics Ltd. our main aim is to offer to our customers the best and most effective solution to meet their
test & measurement needs through exceptional quality and reliability of our products and services.
We take a personal approach to each customer according to his individual needs.